mi_weps查询错误修改
This commit is contained in:
parent
ce8cd2402c
commit
7b2efe8b35
|
@ -44,7 +44,7 @@ public interface DeviceDao extends BaseMapper<Device> {
|
||||||
|
|
||||||
List<DeviceVO> getDeviceVOByIds(@Param("idList") List<Long> deviceIdList);
|
List<DeviceVO> getDeviceVOByIds(@Param("idList") List<Long> deviceIdList);
|
||||||
|
|
||||||
List<DeviceHistoryVO> getPressureChartData(Long deviceId, String startTime, String endTime, String tableName);
|
List<DeviceHistoryVO> getPressureChartData(Long deviceId, String startTime, String endTime, String tableName, String deviceProduct);
|
||||||
|
|
||||||
List<DeviceHistoryVO> getSwitchStatusData(Long deviceId, String startTime, String endTime, String tableName, String deviceProduct);
|
List<DeviceHistoryVO> getSwitchStatusData(Long deviceId, String startTime, String endTime, String tableName, String deviceProduct);
|
||||||
|
|
||||||
|
|
|
@ -37,7 +37,7 @@ public interface DeviceService extends IService<Device> {
|
||||||
|
|
||||||
List<DeviceVO> getDeviceVOByIds(List<Long> deviceIdList);
|
List<DeviceVO> getDeviceVOByIds(List<Long> deviceIdList);
|
||||||
|
|
||||||
List<DeviceHistoryVO> getPressureChartData(Long deviceId, String startTime, String endTime);
|
List<DeviceHistoryVO> getPressureChartData(Long deviceId, String startTime, String endTime, String deviceProduct);
|
||||||
|
|
||||||
List<DeviceHistoryVO> getSwitchStatusData(Long deviceId, String startTime, String endTime, String deviceProduct);
|
List<DeviceHistoryVO> getSwitchStatusData(Long deviceId, String startTime, String endTime, String deviceProduct);
|
||||||
|
|
||||||
|
|
|
@ -282,9 +282,9 @@ public class DeviceServiceImpl extends ServiceImpl<DeviceDao, Device> implements
|
||||||
}
|
}
|
||||||
|
|
||||||
@Override
|
@Override
|
||||||
public List<DeviceHistoryVO> getPressureChartData(Long deviceId, String startTime, String endTime) {
|
public List<DeviceHistoryVO> getPressureChartData(Long deviceId, String startTime, String endTime, String deviceProduct) {
|
||||||
String tableName = Redis2DBPersistenceService.DEFAULT_DATA_TABLE + deviceId;
|
String tableName = Redis2DBPersistenceService.DEFAULT_DATA_TABLE + deviceId;
|
||||||
return this.deviceDao.getPressureChartData(deviceId, startTime, endTime, tableName);
|
return this.deviceDao.getPressureChartData(deviceId, startTime, endTime, tableName, deviceProduct);
|
||||||
}
|
}
|
||||||
|
|
||||||
@Override
|
@Override
|
||||||
|
|
|
@ -101,7 +101,7 @@ public class SummaryServiceImpl implements SummaryService {
|
||||||
}
|
}
|
||||||
List<String> xAxisData = new ArrayList<>();
|
List<String> xAxisData = new ArrayList<>();
|
||||||
|
|
||||||
List<DeviceHistoryVO> dataList = this.deviceService.getPressureChartData(deviceId, startTime, endTime);
|
List<DeviceHistoryVO> dataList = this.deviceService.getPressureChartData(deviceId, startTime, endTime, deviceVO.getProduct().getCode());
|
||||||
//将查询到的结果组装成LineSummaryVO返回给前端
|
//将查询到的结果组装成LineSummaryVO返回给前端
|
||||||
LineSummaryVO lineSummaryVO = new LineSummaryVO();
|
LineSummaryVO lineSummaryVO = new LineSummaryVO();
|
||||||
lineSummaryVO.setTitle(deviceVO.getGasWell().getName());
|
lineSummaryVO.setTitle(deviceVO.getGasWell().getName());
|
||||||
|
|
|
@ -97,27 +97,28 @@
|
||||||
|
|
||||||
|
|
||||||
<select id="historyPage" resultType="com.isu.gaswellwatch.vo.DeviceHistoryVO">
|
<select id="historyPage" resultType="com.isu.gaswellwatch.vo.DeviceHistoryVO">
|
||||||
select t.collection_time,t.oil_pressure,t.cas_pressure,t.pre_pressure
|
select t.collection_time,t.oil_pressure,t.cas_pressure
|
||||||
<choose>
|
<choose>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='knpc'">
|
<when test="deviceProduct!=null and deviceProduct=='knpc'">
|
||||||
,'knpc' as type,t.run_mode,t.status_end_time,t.temperature,t.humidity,t.well_status,t.plug_status
|
,t.pre_pressure,'knpc' as
|
||||||
|
type,t.run_mode,t.status_end_time,t.temperature,t.humidity,t.well_status,t.plug_status
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='etc'">
|
<when test="deviceProduct!=null and deviceProduct=='etc'">
|
||||||
,'etc' as type,t.current_status_remaining_time as statusEndTime
|
,t.pre_pressure,'etc' as type,t.current_status_remaining_time as statusEndTime
|
||||||
,t.controller_current_status as runMode,t.solenoid_valve_status as wellStatus
|
,t.controller_current_status as runMode,t.solenoid_valve_status as wellStatus
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='scss'">
|
<when test="deviceProduct!=null and deviceProduct=='scss'">
|
||||||
,'scss' as type,t.ctl_model as runMode,t.remaining_time_action as statusEndTime
|
,t.pre_pressure,'scss' as type,t.ctl_model as runMode,t.remaining_time_action as statusEndTime
|
||||||
,t.solar_voltage,t.first_solenoid_status as wellStatus
|
,t.solar_voltage,t.first_solenoid_status as wellStatus
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='weps_plug'">
|
<when test="deviceProduct!=null and deviceProduct=='weps_plug'">
|
||||||
,'weps_plug' as type, t.run_mode as runMode
|
,t.pre_pressure,'weps_plug' as type, t.run_mode as runMode
|
||||||
,case t.solenoid_valve_status when 2 then t.open_well_remaining_time
|
,case t.solenoid_valve_status when 2 then t.open_well_remaining_time
|
||||||
when 1 then t.close_well_remaining_time else null end as statusEndTime
|
when 1 then t.close_well_remaining_time else null end as statusEndTime
|
||||||
,case t.solenoid_valve_status when 2 then 1 when 1 then 0 else null end as wellStatus
|
,case t.solenoid_valve_status when 2 then 1 when 1 then 0 else null end as wellStatus
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='mi_weps_plug'">
|
<when test="deviceProduct!=null and deviceProduct=='mi_weps_plug'">
|
||||||
,t.produce_mode as runMode,t.remaining_time as statusEndTime
|
,'mi_weps_plug' as type,t.produce_mode as runMode,t.remaining_time as statusEndTime
|
||||||
,case t.current_status when 0 then 0 else 1 end as wellStatus
|
,case t.current_status when 0 then 0 else 1 end as wellStatus
|
||||||
,t.current_status as plugStatus
|
,t.current_status as plugStatus
|
||||||
</when>
|
</when>
|
||||||
|
@ -161,7 +162,24 @@
|
||||||
</select>
|
</select>
|
||||||
|
|
||||||
<select id="getPressureChartData" resultType="com.isu.gaswellwatch.vo.DeviceHistoryVO">
|
<select id="getPressureChartData" resultType="com.isu.gaswellwatch.vo.DeviceHistoryVO">
|
||||||
select t.collection_time,t.oil_pressure,t.cas_pressure,t.pre_pressure
|
select t.collection_time,t.oil_pressure,t.cas_pressure
|
||||||
|
<choose>
|
||||||
|
<when test="deviceProduct!=null and deviceProduct=='knpc'">
|
||||||
|
,t.pre_pressure,'knpc' as type
|
||||||
|
</when>
|
||||||
|
<when test="deviceProduct!=null and deviceProduct=='etc'">
|
||||||
|
,t.pre_pressure,'etc' as type
|
||||||
|
</when>
|
||||||
|
<when test="deviceProduct!=null and deviceProduct=='scss'">
|
||||||
|
,t.pre_pressure,'scss' as type
|
||||||
|
</when>
|
||||||
|
<when test="deviceProduct!=null and deviceProduct=='weps_plug'">
|
||||||
|
,t.pre_pressure,'weps_plug' as type
|
||||||
|
</when>
|
||||||
|
<when test="deviceProduct!=null and deviceProduct=='mi_weps_plug'">
|
||||||
|
,'mi_weps_plug' as type
|
||||||
|
</when>
|
||||||
|
</choose>
|
||||||
from ${tableName} t
|
from ${tableName} t
|
||||||
<where>
|
<where>
|
||||||
t.device_id = #{deviceId}
|
t.device_id = #{deviceId}
|
||||||
|
@ -203,27 +221,28 @@
|
||||||
|
|
||||||
|
|
||||||
<select id="getDeviceHistoryData" resultType="com.isu.gaswellwatch.vo.DeviceHistoryVO">
|
<select id="getDeviceHistoryData" resultType="com.isu.gaswellwatch.vo.DeviceHistoryVO">
|
||||||
select t.collection_time,t.oil_pressure,t.cas_pressure,t.pre_pressure
|
select t.collection_time,t.oil_pressure,t.cas_pressure
|
||||||
<choose>
|
<choose>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='knpc'">
|
<when test="deviceProduct!=null and deviceProduct=='knpc'">
|
||||||
,'knpc' as type,t.run_mode,t.status_end_time,t.temperature,t.humidity,t.well_status,t.plug_status
|
,t.pre_pressure,'knpc' as
|
||||||
|
type,t.run_mode,t.status_end_time,t.temperature,t.humidity,t.well_status,t.plug_status
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='etc'">
|
<when test="deviceProduct!=null and deviceProduct=='etc'">
|
||||||
,'etc' as type,t.current_status_remaining_time as statusEndTime
|
,t.pre_pressure,'etc' as type,t.current_status_remaining_time as statusEndTime
|
||||||
,t.controller_current_status as runMode,t.solenoid_valve_status as wellStatus
|
,t.controller_current_status as runMode,t.solenoid_valve_status as wellStatus
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='scss'">
|
<when test="deviceProduct!=null and deviceProduct=='scss'">
|
||||||
,'scss' as type,t.ctl_model as runMode,t.remaining_time_action as statusEndTime
|
,t.pre_pressure,'scss' as type,t.ctl_model as runMode,t.remaining_time_action as statusEndTime
|
||||||
,t.solar_voltage,t.first_solenoid_status as wellStatus
|
,t.solar_voltage,t.first_solenoid_status as wellStatus
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='weps_plug'">
|
<when test="deviceProduct!=null and deviceProduct=='weps_plug'">
|
||||||
,'weps_plug' as type, t.run_mode as runMode
|
,t.pre_pressure,'weps_plug' as type, t.run_mode as runMode
|
||||||
,case t.solenoid_valve_status when 2 then t.open_well_remaining_time
|
,case t.solenoid_valve_status when 2 then t.open_well_remaining_time
|
||||||
when 1 then t.close_well_remaining_time else null end as statusEndTime
|
when 1 then t.close_well_remaining_time else null end as statusEndTime
|
||||||
,case t.solenoid_valve_status when 2 then 1 when 1 then 0 else null end as wellStatus
|
,case t.solenoid_valve_status when 2 then 1 when 1 then 0 else null end as wellStatus
|
||||||
</when>
|
</when>
|
||||||
<when test="deviceProduct!=null and deviceProduct=='mi_weps_plug'">
|
<when test="deviceProduct!=null and deviceProduct=='mi_weps_plug'">
|
||||||
,t.produce_mode as runMode,t.remaining_time as statusEndTime
|
,'mi_weps_plug' as type,t.produce_mode as runMode,t.remaining_time as statusEndTime
|
||||||
,case t.current_status when 0 then 0 else 1 end as wellStatus
|
,case t.current_status when 0 then 0 else 1 end as wellStatus
|
||||||
,t.current_status as plugStatus
|
,t.current_status as plugStatus
|
||||||
</when>
|
</when>
|
||||||
|
|
Loading…
Reference in New Issue