knpc添加电压字段
This commit is contained in:
parent
b351dd4475
commit
d56fe465d7
|
@ -33,6 +33,7 @@ public class Knpcv1PersistenceHandler extends AbstractPersistenceHandler {
|
||||||
KNPC_V1_COLUMN_MAPPING_MAP.put("liquid_level", "liquidLevel");
|
KNPC_V1_COLUMN_MAPPING_MAP.put("liquid_level", "liquidLevel");
|
||||||
KNPC_V1_COLUMN_MAPPING_MAP.put("temperature", "temperature");
|
KNPC_V1_COLUMN_MAPPING_MAP.put("temperature", "temperature");
|
||||||
KNPC_V1_COLUMN_MAPPING_MAP.put("humidity", "humidity");
|
KNPC_V1_COLUMN_MAPPING_MAP.put("humidity", "humidity");
|
||||||
|
KNPC_V1_COLUMN_MAPPING_MAP.put("battery_Voltage", "batteryVoltage");
|
||||||
KNPC_V1_COLUMN_MAPPING_MAP.put("op_mode", "opmode");
|
KNPC_V1_COLUMN_MAPPING_MAP.put("op_mode", "opmode");
|
||||||
KNPC_V1_COLUMN_MAPPING_MAP.put("timer_able1", "timer1");
|
KNPC_V1_COLUMN_MAPPING_MAP.put("timer_able1", "timer1");
|
||||||
KNPC_V1_COLUMN_MAPPING_MAP.put("timer_able2", "timer2");
|
KNPC_V1_COLUMN_MAPPING_MAP.put("timer_able2", "timer2");
|
||||||
|
@ -140,6 +141,7 @@ public class Knpcv1PersistenceHandler extends AbstractPersistenceHandler {
|
||||||
Knpcv1PersistenceHandler.this.setValue(ps, newRow, 51, "tpClosePressure", Types.INTEGER);
|
Knpcv1PersistenceHandler.this.setValue(ps, newRow, 51, "tpClosePressure", Types.INTEGER);
|
||||||
Knpcv1PersistenceHandler.this.setValue(ps, newRow, 52, "tpCloseTime", Types.VARCHAR);
|
Knpcv1PersistenceHandler.this.setValue(ps, newRow, 52, "tpCloseTime", Types.VARCHAR);
|
||||||
Knpcv1PersistenceHandler.this.setValue(ps, newRow, 53, "tpStabilityTime", Types.INTEGER);
|
Knpcv1PersistenceHandler.this.setValue(ps, newRow, 53, "tpStabilityTime", Types.INTEGER);
|
||||||
|
Knpcv1PersistenceHandler.this.setValue(ps, newRow, 54, "batteryVoltage", Types.DECIMAL);
|
||||||
return ps.executeUpdate();
|
return ps.executeUpdate();
|
||||||
}
|
}
|
||||||
});
|
});
|
||||||
|
|
|
@ -0,0 +1,86 @@
|
||||||
|
INSERT INTO `command_points` (`id`, `command_id`, `field`, `name`, `details`, `start_address`, `step_size`, `factor`, `precision`, `use_hex`, `byte_order`, `format`, `decode_name`)
|
||||||
|
VALUES (10055, 10001, 'batteryVoltage', '电池电压', '单位: V, *100', 22, 11, 100.00, 2, NULL, NULL, NULL, 'factor');
|
||||||
|
|
||||||
|
-- 77台设备
|
||||||
|
select concat('ALTER TABLE `t_device_data_', id, '` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT \'电池电压:单位V, *100\' AFTER `humidity`;') add_sql from device where product = 4;
|
||||||
|
|
||||||
|
ALTER TABLE `t_device_data_10` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_224` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_226` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_228` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_229` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_230` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_231` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_240` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_251` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_254` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_264` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_265` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_270` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_274` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_275` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_282` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_284` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_285` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_286` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_287` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_306` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_307` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_308` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_309` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_316` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_335` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_337` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_339` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_342` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_344` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_345` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_346` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_347` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_348` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_353` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_354` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_355` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_356` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_357` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_358` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_359` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_360` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_361` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_362` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_374` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_375` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_376` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_377` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_378` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_379` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_380` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_381` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_382` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_383` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_386` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_387` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_388` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_389` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_390` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_391` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_392` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_393` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_394` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_395` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_398` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_414` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_415` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_416` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_417` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_418` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_427` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_433` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_434` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_435` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_436` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_438` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
ALTER TABLE `t_device_data_889` ADD COLUMN `battery_voltage` decimal(10, 2) NULL COMMENT '电池电压:单位V, *100' AFTER `humidity`;
|
||||||
|
|
||||||
|
|
||||||
|
|
|
@ -18,6 +18,7 @@ CREATE TABLE `$TableName$`
|
||||||
`liquid_level` decimal(10, 2) NULL DEFAULT NULL COMMENT '流量:单位mm',
|
`liquid_level` decimal(10, 2) NULL DEFAULT NULL COMMENT '流量:单位mm',
|
||||||
`temperature` decimal(10, 2) NULL DEFAULT NULL COMMENT '温度:单位℃,*100,最高位表示正负,0正1负,即零下的温度加32768',
|
`temperature` decimal(10, 2) NULL DEFAULT NULL COMMENT '温度:单位℃,*100,最高位表示正负,0正1负,即零下的温度加32768',
|
||||||
`humidity` decimal(10, 2) NULL DEFAULT NULL COMMENT '湿度:单位%',
|
`humidity` decimal(10, 2) NULL DEFAULT NULL COMMENT '湿度:单位%',
|
||||||
|
`battery_voltage` decimal(10, 2) NULL DEFAULT NULL COMMENT '电池电压:单位V, *100',
|
||||||
`op_mode` smallint NULL DEFAULT NULL COMMENT '运行模式:\r\n0: 手动模式 hand_mode\r\n1:定时器模式 timer_mode\r\n2:计时器模式 t2mode\r\n3:压力模式 pressure_mode\r\n4:柱塞模式 piston_mode\r\n5:时压模式 tp_mode',
|
`op_mode` smallint NULL DEFAULT NULL COMMENT '运行模式:\r\n0: 手动模式 hand_mode\r\n1:定时器模式 timer_mode\r\n2:计时器模式 t2mode\r\n3:压力模式 pressure_mode\r\n4:柱塞模式 piston_mode\r\n5:时压模式 tp_mode',
|
||||||
`timer_able1` smallint NULL DEFAULT NULL COMMENT '定时模式定时器1使能:\r\n0:禁止 disable\r\n1:使能 enable',
|
`timer_able1` smallint NULL DEFAULT NULL COMMENT '定时模式定时器1使能:\r\n0:禁止 disable\r\n1:使能 enable',
|
||||||
`timer_able2` smallint NULL DEFAULT NULL COMMENT '定时模式定时器2使能:\r\n0:禁止 disable\r\n1:使能 ',
|
`timer_able2` smallint NULL DEFAULT NULL COMMENT '定时模式定时器2使能:\r\n0:禁止 disable\r\n1:使能 ',
|
||||||
|
|
|
@ -9,56 +9,58 @@ INSERT INTO `$TableName$` (`id`, `device_id`, `created_time`, `collection_time`,
|
||||||
`open_well_limit_max`, `open_well_limit_min`, `plug_init_status`, `plug_sustain_time`,
|
`open_well_limit_max`, `open_well_limit_min`, `plug_init_status`, `plug_sustain_time`,
|
||||||
`plug_close_time`, `tp_init_status`, `tp_open_source`, `tp_open_trigger`,
|
`plug_close_time`, `tp_init_status`, `tp_open_source`, `tp_open_trigger`,
|
||||||
`tp_open_pressure`, `tp_open_time`, `tp_close_source`, `tp_close_trigger`,
|
`tp_open_pressure`, `tp_open_time`, `tp_close_source`, `tp_close_trigger`,
|
||||||
`tp_close_pressure`, `tp_close_time`, `tp_stability_time`)
|
`tp_close_pressure`, `tp_close_time`, `tp_stability_time`, `battery_voltage`)
|
||||||
VALUES (?, ?, NOW(), ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?,
|
VALUES (?, ?, NOW(), ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?,
|
||||||
?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?)
|
?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?) ON DUPLICATE KEY
|
||||||
ON DUPLICATE KEY UPDATE receive_time=VALUES(receive_time),
|
UPDATE receive_time=
|
||||||
device_time=VALUES(device_time),
|
VALUES (receive_time), device_time=
|
||||||
run_mode=VALUES(run_mode),
|
VALUES (device_time), run_mode=
|
||||||
well_status=VALUES(well_status),
|
VALUES (run_mode), well_status=
|
||||||
plug_status=VALUES(plug_status),
|
VALUES (well_status), plug_status=
|
||||||
status_start_time=VALUES(status_start_time),
|
VALUES (plug_status), status_start_time=
|
||||||
status_end_time=VALUES(status_end_time),
|
VALUES (status_start_time), status_end_time=
|
||||||
oil_pressure=VALUES(oil_pressure),
|
VALUES (status_end_time), oil_pressure=
|
||||||
cas_pressure=VALUES(cas_pressure),
|
VALUES (oil_pressure), cas_pressure=
|
||||||
pre_pressure=VALUES(pre_pressure),
|
VALUES (cas_pressure), pre_pressure=
|
||||||
pipe_pressure=VALUES(pipe_pressure),
|
VALUES (pre_pressure), pipe_pressure=
|
||||||
liquid_level=VALUES(liquid_level),
|
VALUES (pipe_pressure), liquid_level=
|
||||||
temperature=VALUES(temperature),
|
VALUES (liquid_level), temperature=
|
||||||
humidity=VALUES(humidity),
|
VALUES (temperature), humidity=
|
||||||
op_mode=VALUES(op_mode),
|
VALUES (humidity), battery_voltage=
|
||||||
timer_able1=VALUES(timer_able1),
|
VALUES (battery_voltage), op_mode=
|
||||||
timer_able2=VALUES(timer_able2),
|
VALUES (op_mode), timer_able1=
|
||||||
timer_open1=VALUES(timer_open1),
|
VALUES (timer_able1), timer_able2=
|
||||||
timer_close1=VALUES(timer_close1),
|
VALUES (timer_able2), timer_open1=
|
||||||
timer_open2=VALUES(timer_open2),
|
VALUES (timer_open1), timer_close1=
|
||||||
timer_close2=VALUES(timer_close2),
|
VALUES (timer_close1), timer_open2=
|
||||||
timing_open=VALUES(timing_open),
|
VALUES (timer_open2), timer_close2=
|
||||||
timing_close=VALUES(timing_close),
|
VALUES (timer_close2), timing_open=
|
||||||
timing_delay=VALUES(timing_delay),
|
VALUES (timing_open), timing_close=
|
||||||
presource=VALUES(presource),
|
VALUES (timing_close), timing_delay=
|
||||||
pressure_open=VALUES(pressure_open),
|
VALUES (timing_delay), presource=
|
||||||
pressure_close=VALUES(pressure_close),
|
VALUES (presource), pressure_open=
|
||||||
trigger_type=VALUES(trigger_type),
|
VALUES (pressure_open), pressure_close=
|
||||||
stability_time=VALUES(stability_time),
|
VALUES (pressure_close), trigger_type=
|
||||||
max_open_well=VALUES(max_open_well),
|
VALUES (trigger_type), stability_time=
|
||||||
max_close_well=VALUES(max_close_well),
|
VALUES (stability_time), max_open_well=
|
||||||
min_open_well=VALUES(min_open_well),
|
VALUES (max_open_well), max_close_well=
|
||||||
min_close_well=VALUES(min_close_well),
|
VALUES (max_close_well), min_open_well=
|
||||||
prespro_tect=VALUES(prespro_tect),
|
VALUES (min_open_well), min_close_well=
|
||||||
prespro_source=VALUES(prespro_source),
|
VALUES (min_close_well), prespro_tect=
|
||||||
open_well_limit_max=VALUES(open_well_limit_max),
|
VALUES (prespro_tect), prespro_source=
|
||||||
open_well_limit_min=VALUES(open_well_limit_min),
|
VALUES (prespro_source), open_well_limit_max=
|
||||||
plug_init_status=VALUES(plug_init_status),
|
VALUES (open_well_limit_max), open_well_limit_min=
|
||||||
plug_sustain_time=VALUES(plug_sustain_time),
|
VALUES (open_well_limit_min), plug_init_status=
|
||||||
plug_close_time=VALUES(plug_close_time),
|
VALUES (plug_init_status), plug_sustain_time=
|
||||||
tp_init_status=VALUES(tp_init_status),
|
VALUES (plug_sustain_time), plug_close_time=
|
||||||
tp_open_source=VALUES(tp_open_source),
|
VALUES (plug_close_time), tp_init_status=
|
||||||
tp_open_trigger=VALUES(tp_open_trigger),
|
VALUES (tp_init_status), tp_open_source=
|
||||||
tp_open_pressure=VALUES(tp_open_pressure),
|
VALUES (tp_open_source), tp_open_trigger=
|
||||||
tp_open_time=VALUES(tp_open_time),
|
VALUES (tp_open_trigger), tp_open_pressure=
|
||||||
tp_close_source=VALUES(tp_close_source),
|
VALUES (tp_open_pressure), tp_open_time=
|
||||||
tp_close_trigger=VALUES(tp_close_trigger),
|
VALUES (tp_open_time), tp_close_source=
|
||||||
tp_close_pressure=VALUES(tp_close_pressure),
|
VALUES (tp_close_source), tp_close_trigger=
|
||||||
tp_close_time=VALUES(tp_close_time),
|
VALUES (tp_close_trigger), tp_close_pressure=
|
||||||
tp_stability_time=VALUES(tp_stability_time)
|
VALUES (tp_close_pressure), tp_close_time=
|
||||||
|
VALUES (tp_close_time), tp_stability_time=
|
||||||
|
VALUES (tp_stability_time)
|
Loading…
Reference in New Issue