CREATE TABLE `$TableName$` ( `id` bigint NOT NULL COMMENT '主键', `device_id` int NOT NULL COMMENT '设备标识', `created_time` datetime NOT NULL COMMENT '数据落库时间', `collection_time` datetime NOT NULL COMMENT '采集指令下发时间', `receive_time` datetime NOT NULL COMMENT '接收到数据时间', `cas_pressure` decimal(10, 2) NULL DEFAULT NULL COMMENT '套压', `oil_pressure` decimal(10, 2) NULL DEFAULT NULL COMMENT '油压', `first_solenoid_status` int NULL DEFAULT NULL COMMENT '当前第一个电磁阀状态', `battery_voltage` decimal(10, 1) NULL DEFAULT NULL COMMENT '电池电压', `solar_voltage` decimal(10, 1) NULL DEFAULT NULL COMMENT '太阳能电压', `remaining_time_action` int NULL DEFAULT NULL COMMENT '动作剩余时间', `second_solenoid_status` int NULL DEFAULT NULL COMMENT '第二个电磁阀状态', `pre_pressure` int NULL DEFAULT NULL COMMENT '输压', `internet_traffic` int NULL DEFAULT NULL COMMENT '流量', `load_factor` int NULL DEFAULT NULL COMMENT '载荷因子', `data_time` datetime NULL DEFAULT NULL COMMENT '日期时间', `show_delay` int NULL DEFAULT NULL COMMENT '显示延时', `open_well_sampling_interval` int NULL DEFAULT NULL COMMENT '开井采样间隔', `close_well_sampling_interval` int NULL DEFAULT NULL COMMENT '关井采样间隔', `ctl_model` int NULL DEFAULT NULL COMMENT '控制模式', `min_pressure` decimal(10, 2) NULL DEFAULT NULL COMMENT '套压最小值', `max_pressure` decimal(10, 2) NULL DEFAULT NULL COMMENT '套压最大值', `pressure_min_voltage` decimal(10, 2) NULL DEFAULT NULL COMMENT '套压最小电压', `pressure_max_voltage` decimal(10, 2) NULL DEFAULT NULL COMMENT '套压最大电压', `oil_min` decimal(10, 2) NULL DEFAULT NULL COMMENT '油压最小值', `oil_max` decimal(10, 2) NULL DEFAULT NULL COMMENT '油压最大值', `oil_min_voltage` decimal(10, 2) NULL DEFAULT NULL COMMENT '油压最小电压', `oil_max_voltage` decimal(10, 2) NULL DEFAULT NULL COMMENT '油压最大电压', `input_pressure_min_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '输压最小值', `input_pressure_max_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '输压最大值', `input_voltage_min_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '输压最小电压', `input_voltage_max_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '输压最大电压', `flow_rate_min_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '流量最小值', `flow_rate_max_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '流量最大值', `flow_voltage_min_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '流量最小电压', `flow_voltage_max_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '流量最大电压', `continuous_sampling_interval_duration` int NULL DEFAULT NULL COMMENT '连续采样间隔', `sensor_signal_effective_level` decimal(10, 2) NULL DEFAULT NULL COMMENT '到达传感器有效电平', `pressure_compensation_polarity_flag` int NULL DEFAULT NULL COMMENT '套压补偿极性', `pressure_compensation_value_setting` int NULL DEFAULT NULL COMMENT '套压补偿值', `oil_pressure_compensation_polarity_flag` int NULL DEFAULT NULL COMMENT '油压补偿极性', `oil_pressure_compensation_value_setting` int NULL DEFAULT NULL COMMENT '油压补偿值', `input_pressure_compensation_polarity_flag` int NULL DEFAULT NULL COMMENT '输压补偿极性', `input_pressure_compensation_value_setting` int NULL DEFAULT NULL COMMENT '输压补偿值', `flow_compensation_polarity_flag` int NULL DEFAULT NULL COMMENT '流量补偿极性', `flow_compensation_value_setting` int NULL DEFAULT NULL COMMENT '流量补偿值', `well_open_time_timestamp` varchar(10) NULL DEFAULT NULL COMMENT '开井时间', `well_open_pressure_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '开井套压', `well_open_oil_pressure_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '开井油压', `well_open_load_factor_presets` decimal(10, 2) NULL DEFAULT NULL COMMENT '开井载荷因子预设值', `well_close_time_timestamp` varchar(10) NULL DEFAULT NULL COMMENT '关井时间时间戳', `well_close_pressure_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '关井压力值', `well_close_oil_pressure_value` decimal(10, 2) NULL DEFAULT NULL COMMENT '关井油压值', `well_close_flow_value` int NULL DEFAULT NULL COMMENT '关井流量值', `min_well_open_time_duration` varchar(10) NULL DEFAULT NULL COMMENT '最小开井时间持续时长', `max_well_open_time_duration` varchar(10) NULL DEFAULT NULL COMMENT '最大开井时间持续时长', `min_well_close_time_duration` varchar(10) NULL DEFAULT NULL COMMENT '最小关井时间持续时长', `max_well_close_time_duration` varchar(10) NULL DEFAULT NULL COMMENT '最大关井时间持续时长', `pressure_stabilization_duration` varchar(10) NULL DEFAULT NULL COMMENT '压力稳定持续时长', `flow_stabilization_duration` varchar(10) NULL DEFAULT NULL COMMENT '流量稳定持续时长', `load_factor_stabilization_duration` varchar(10) NULL DEFAULT NULL COMMENT '载荷因子稳定持续时长', `plunger_delay_duration` varchar(10) NULL DEFAULT NULL COMMENT '柱塞延迟时长', `plunger_rise_duration` varchar(10) NULL DEFAULT NULL COMMENT '柱塞上升时长', `continuos_flow_duration` varchar(10) NULL DEFAULT NULL COMMENT '连续流量持续时长', `well_close_time_duration` varchar(10) NULL DEFAULT NULL COMMENT '关井时间持续时长', `well_close_time_not_reached_duration` varchar(10) NULL DEFAULT NULL COMMENT '关井时间未达到持续时长', `well_close_not_reached_count_value` int NULL DEFAULT NULL COMMENT '关井未达到次数值', `plunger_delay_duration_repeat` int NULL DEFAULT NULL COMMENT '柱塞延迟时长重复次数', `target_time_timestamp` int NULL DEFAULT NULL COMMENT '目标时间时间戳', `target_time_range_value` int NULL DEFAULT NULL COMMENT '目标时间范围值', `continuos_flow_increase_duration` varchar(10) NULL DEFAULT NULL COMMENT '连续流量增加持续时长', `continuos_flow_decrease_duration` varchar(10) NULL DEFAULT NULL COMMENT '连续流量减少持续时长', `well_close_increase_duration` varchar(10) NULL DEFAULT NULL COMMENT '关井增加持续时长', `well_close_decrease_duration` varchar(10) NULL DEFAULT NULL COMMENT '关井减少持续时长', `min_well_close_time_duration2` varchar(10) NULL DEFAULT NULL COMMENT '最小关井时间持续时长', `max_well_close_time_duration2` varchar(10) NULL DEFAULT NULL COMMENT '最大关井时间持续时长', `min_continous_flow_time_duration` varchar(10) NULL DEFAULT NULL COMMENT '最小连续流量时间持续时长', `max_continous_flow_time_duration` varchar(10) NULL DEFAULT NULL COMMENT '最大连续流量时间持续时长', `min_well_open_time_duration2` varchar(10) NULL DEFAULT NULL COMMENT '最小开井时间持续时长', `max_well_open_time_duration2` varchar(10) NULL DEFAULT NULL COMMENT '最大开井时间持续时长', `well_open_pressure_value_at_open` int NULL DEFAULT NULL COMMENT '开井时压力值(开井瞬间)', `well_open_oil_pressure_value_at_open` int NULL DEFAULT NULL COMMENT '开井时油压值(开井瞬间)', `well_open_load_factor_presets_at_open` int NULL DEFAULT NULL COMMENT '开井时载荷因子预设值(开井瞬间)', `well_close_pressure_value_at_close` int NULL DEFAULT NULL COMMENT '关井时压力值(关井瞬间)', `well_close_oil_ppressure_value_at_close` int NULL DEFAULT NULL COMMENT '关井时油压值(关井瞬间)', `well_close_flow_value_at_close` int NULL DEFAULT NULL COMMENT '关井时流量值(关井瞬间)', PRIMARY KEY (`id`) USING BTREE, UNIQUE INDEX `udx_device_create_time` (`device_id` ASC, `collection_time` ASC) USING BTREE COMMENT '设备采集数据唯一键' ) ENGINE = InnoDB COMMENT = '设备ID:$DeviceId$的采集数据'